Katchalski, Tsvi; Case, Tom; Kim, Keun-young; Ramachandra, Ranjan; Bushong, Eric; Deerinck, Thomas J.; Haberl, Matthias; Mackey, Mason; Peltier, Steven; Castillon, Guillaume; Fujikawa, Nobuko; Lawrence, Albert; Ellisman, Mark (2021). CIL:50351, Mus musculus, Spinal cord neuron. In Cell Image Library. UC San Diego Library Digital Collections. Dataset. https://doi.org/10.6075/J0PV6J1M
- Description
-
Biological samples are frequently stained with heavy metals in preparation for examining the macro, micro and ultra-structure using X-ray microtomography and electron microscopy. A single X-ray microtomography scan reveals detailed 3D structure based on staining density, yet it lacks both material composition and functional information. Using a commercially available polychromatic X-ray source, energy integrating detectors and a two-scan configuration labelled by their energy- High and Low, we demonstrate how a specific element, here shown with iron, can be detected from a mixture with other heavy metals. With proper selection of scan configuration, achieving strong overlap of source characteristic emission lines and iron K-edge absorption, iron absorption was enhanced enabling K-edge imaging. Specifically, iron images were obtained by scatter plot material analysis, after selecting specific regions within scatter plots generated from the High and Low scans. Using this method, we identified iron rich regions associated with an iron staining reaction that marks the nodes of Ranvier along nerve axons within mouse spinal roots, also stained with osmium metal commonly used for electron microscopy.
60kVp with fe filtration. - Date Issued
- 2021
- Researchers
- Methods
-
XRM was performed on a Versa 510, (Carl Zeiss X-ray Microscopy, Pleasanton, CA 94588). The Versa 510 is equipped with a polychromatic tungsten source, tunable in the voltage range 30-160kVp. Scan configuration: "Low" -30kVp peak tube potential without filtration, exposure time 20-90sec. "High"-60kVp peak tube potential, filtration 25μm thick iron filter, exposure time 10-120sec. Common scan conditions: binning 1, source-rotation axis distance 7.5mm, detector-rotation axis distance 5mm, pixel size 0.394μm, optical magnification x20, rotation angle -180° to +180°, number of views 3201. Iron filtration used a 0.001"x1"x2" foil placed at the X-ray tube exit slit. The foil was of 3N5 purity and sold by ESPI Metals, Ashland, OR 97520.
- Technical Details
-
Item type: recorded image
Imaging mode: X-ray micrograph
Source of contrast: Fe and Os staining - Series
- Scientific Name
- Anatomy
Formats
View formats within this collection
- Language
- No linguistic content; Not applicable
- Identifier
-
Samplenumber: 50351
- Related Resources
- Source Record in the Cell Image Library: https://doi.org/10.7295/W9CIL50351
- Katchalski, T., Case, T., Kim, Ky. et al. Iron-specific Signal Separation from within Heavy Metal Stained Biological Samples Using X-Ray Microtomography with Polychromatic Source and Energy-Integrating Detectors. Sci Rep 8, 7553 (2018). https://doi.org/10.1038/s41598-018-25099-z
Source data
Reference
- License
- Copyright
-
Creative Commons Public Domain Dedication
Use: The person(s) who associated a work with this deed has dedicated the work to the public domain by waiving all of their rights to the work worldwide under copyright law, including all related and neighboring rights, to the extent allowed by law.
Constraint(s) on Use: This work may be used without prior permission.
- Digital Object Made Available By
-
Research Data Curation Program, UC San Diego, La Jolla, 92093-0175 (https://lib.ucsd.edu/rdcp)
- Last Modified
2022-08-12